portable gasoline powered generator for telecom sites

This gasoline generator designed for communication base station has become an important tool to guarantee the continuous operation of communication base station with its stable power output and low noise. It is not only suitable for areas with unstable power supply, but also can reduce the electromagnetic interference to the equipment through optimized design, ensuring the base station equipment to run stably for a long time.

Description

In modern communication networks, communication base station as a key node of information transmission, its stable power supply is crucial. Especially in areas that lack grid coverage or under unstable power environments, standby generators have become the core of power protection for communication base stations. Traditional gasoline generators often cause communication base station equipment to malfunction and affect network services due to unstable voltage, frequency fluctuations and high harmonic reflections.
In order to solve these problems, we have specially designed a gasoline generator for communication base stations. The generator is optimized according to the load characteristics of the base station, which not only improves the stability and reliability of the equipment, but also effectively reduces the electromagnetic interference to the base station and ensures that the network equipment operates stably under various working conditions.

Features

  • Optimized design specifically for communication base stations:

    • Strong adaptability to non-linear loads: The rectifier module used in communication base stations belongs to the typical non-linear loads, and traditional generators often have abnormal output voltages under such loads, even damaging the equipment. Our generators are configured with independent excitation system, which significantly reduces this voltage instability problem and ensures the stable operation of base station equipment under various load conditions.
    • Brushless design and steel shell structure: The generator adopts brushless generator design, equipped with steel shell casing, which not only reduces mechanical wear and tear, but also greatly reduces the distortion of the voltage waveform, improves the quality of power, ensures a smoother output waveform, and reduces the electromagnetic interference to the base station.
  • High efficiency and low noise:

    • Double-cylinder four-stroke engine: The generator is equipped with a double-cylinder four-stroke engine with high power output and low fuel consumption. The engine’s large bore and large stroke design improves the working efficiency and ensures low noise and low emission while increasing the power, which is in line with the environmental protection requirements.
    • Imported engine support: Kohler, Honda and other well-known brands of engines can be selected, with higher operational reliability and durability, suitable for long time high load work.
  • Electromagnetic interference optimization:

    • Damped motor design: In order to reduce electromagnetic interference, we have specially designed a damped motor for the generator. By optimizing the electromagnetic design and adding the rotor damping bar and stator diagonal groove, it effectively reduces the electromagnetic wave interference, ensures the waveform of power output is purer, and reduces the impact on the base station.
  • Easy to move and transport:

    • Ruggedized frame design and roller system: The generator adopts open-frame ruggedized frame design and comes standard with 4 mobile rollers, which is easy to move in the field and under different working environments, and is suitable for a variety of occasions of temporary power demand.
  • Long time running with automatic switching:

    • Metal large-capacity fuel tank: The generator is equipped with a large-capacity metal fuel tank, which can ensure long-time continuous operation and reduce the need for stopping to refuel in the middle of the day, thus improving the working efficiency and reducing manual intervention.
    • Automatic switching device (ATS): In the event of grid power failure, the generator can automatically start and switch the power supply to ensure uninterrupted operation of the communication base station.
  • Rated power and reliability:

    • The rated power is 7 kilowatts, which is applicable to the power demand of most communication base stations, such as small and medium-sized base stations, and can meet the requirements of high-load work and stable power supply.

Working Principle

This gasoline generator converts mechanical energy into electrical energy through the internal combustion engine. The internal combustion engine adopts a four-stroke twin-cylinder design with strong power output, which drives the generator to produce alternating current (AC). The AC power is converted into DC power through the rectifier module, providing stable power support for the equipment in the communication base station.
The independent excitation system of the generator effectively controls the output voltage and avoids voltage fluctuation. The damped motor design reduces electromagnetic interference and improves the quality of output power, thus reducing the impact on base station equipment. In addition, the generator is equipped with an automatic switching device (ATS) that can automatically switch to the generator power supply in the event of a grid failure, ensuring uninterrupted operation of the base station.

Application Areas

  • Communication base station: This gasoline generator is suitable for communication base station, especially located in remote areas or areas with unstable power supply. Through optimized design, it can meet the high requirements of base stations for power stability and reliability, and ensure the continuous operation of base station equipment.
  • Emergency backup power: In the case of grid interruption or unstable power supply, the generator can be used as an emergency backup power supply, which can quickly start and provide stable power support.
  • Field communication application: It is suitable for field operation, temporary construction of communication facilities or emergency communication sites, especially in remote areas not covered by the power grid. Through its strong power and convenient transportation design, it can be quickly put into use to solve the temporary power demand.
  • Unattended base station: With the ability of automatic switching and long time stable operation, this generator is very suitable for unattended base stations, providing stable power support and reducing the need for manual management.
  • Temporary power supply: In the need for temporary power supply site, such as construction projects, mining, field research, etc., the generator can provide flexible and efficient power security.
Technical Parameters
portable gasoline powered generator for telecom sites
ModelMT7
Rated voltage230Vac, 50Hz
Rated power7.0kw
Max power7.5kw
Engine192FD
TypeDual-cylinder four-stroke air-cooled OHV
Fuel tank capacity25L
Oil Capacity1.1L
Starting Systemelectric start
fuel oilUnleaded gasoline above 90#
Net weight93kg
Dimension(LxWxH)(mm)690x540x570 mm